Honeywell Sensepoint XCD Single -Gas Detector
Honeywell Sensepoint XCD Single -Gas Detector is supplied by Guangqun, It can offer you Honeywell Sensepoint XCD Single -Gas Detectorr price, If you needHoneywell Sensepoint XCDo Portable Toxic gas detector pls contact us.
Email:
info@hn-guangqun.com
Phone:
+86-13838155309
Detailed Product Description
Honeywell Sensepoint XCD Single -Gas Detector
Honeywell Sensepoint XCD Single -Gas Detector Technical Parameters
Use:3-wire, 4-20mA, gas detector transmitter for use with directly installed flammable and toxic gas sensors. For the protection of personnel and plant from flammable and toxic gas hazards.
Input Voltage Range: STD&RFD: 16 to 32Vdc (24Vdc nominal), RTD: 18 to 32Vdc (24Vdc nominal)
Power Consumption: ECC = 3.7W, IR = 3.7W, Cat = 4.9W
Current output:4-20mA (Source or Sink)
≥0.0<1.0 mA Fault
4.0 mA to 20.0 mA Normal gas measurement
2.0 mA or 4.0 mA (17.4 mA) Inhibit (during configuration/user settings)
22.0 mA Maximum over range
Terminals:15 (STD), 18(RTD&RFD) x screw terminals suitable for wire diameter 0.5mm 2(20AWG) to 2.5mm 2 (13AWG)
Relays:3 x 5A@250VAC. Selectable normally open or normally closed (Terminal) and
energized/de-energized (programmable)
Communication:RS485 Modbus RTU
Transmitter Material:Epoxy painted LM25 Aluminium. Stainless Steel 316
Sensor Material:Stainless Steel 316
Weight:LM25 Aluminium Alloy :2.4kg. Stainless Steel 316: 4.5 kg
Mounting:Pole or wall mounting
Entries:2 x M20 (or 2 x ¾”NPT) field cable entries, 1 x M25 sensor entry
Repeatability:+/- 1% of FSD
Linearity:+/- 1% of FSD
Accuracy:< +/- 5% of FSD (O2, CO, H2S, FL-CAT)
Response Time:T50 = <15s, T90= <30s (FL CAT and IR sensors)
IP Rating:IP66 in accordance with EN60529:1992
Operating:Temperature -40ºC to +65ºC/ -40ºF to +149ºF.
Operating:Humidity Continuous 20-90%RH (non condensing), Intermittent 10-99%RH (non condensing)
Operating:Pressure 90-110kPa
Storage:Conditions -25°C to +65°C (-13°F to +149°F)
Features of Honeywell Sensepoint XCD Single -Gas Detector
1.Common transmitter platform
2.Clear and informative display
3.Multiple signal outputs
4.Surecell TM and ReflexTM
5.Infrared sensing technologythrhgrfhgrfh
6.Non-intrusive operation
7.Housing material options
8.Easy to install
Product Description of Honeywell Sensepoint XCD Single -Gas Detector
Company Advantage
1.5% lower prices than other competitors
2.Fast delivery
Parts of products are available in stock and can send within 3 working days
3.100% Inspection before Shipment
4.More than 10 years of export experience
5.Certificates UL Class,CSA, ATEX,IECEx, CE, CQST
6.After-sales Service
All the products have 1 year warranty, and It will be free from maintenance within warranty period, products over warranty period for paid services.
Honeywell Sensepoint XCD Single -Gas Detector Technical Parameters
Use:3-wire, 4-20mA, gas detector transmitter for use with directly installed flammable and toxic gas sensors. For the protection of personnel and plant from flammable and toxic gas hazards.
Input Voltage Range: STD&RFD: 16 to 32Vdc (24Vdc nominal), RTD: 18 to 32Vdc (24Vdc nominal)
Power Consumption: ECC = 3.7W, IR = 3.7W, Cat = 4.9W
Current output:4-20mA (Source or Sink)
≥0.0<1.0 mA Fault
4.0 mA to 20.0 mA Normal gas measurement
2.0 mA or 4.0 mA (17.4 mA) Inhibit (during configuration/user settings)
22.0 mA Maximum over range
Terminals:15 (STD), 18(RTD&RFD) x screw terminals suitable for wire diameter 0.5mm 2(20AWG) to 2.5mm 2 (13AWG)
Relays:3 x 5A@250VAC. Selectable normally open or normally closed (Terminal) and
energized/de-energized (programmable)
Communication:RS485 Modbus RTU
Transmitter Material:Epoxy painted LM25 Aluminium. Stainless Steel 316
Sensor Material:Stainless Steel 316
Weight:LM25 Aluminium Alloy :2.4kg. Stainless Steel 316: 4.5 kg
Mounting:Pole or wall mounting
Entries:2 x M20 (or 2 x ¾”NPT) field cable entries, 1 x M25 sensor entry
Repeatability:+/- 1% of FSD
Linearity:+/- 1% of FSD
Accuracy:< +/- 5% of FSD (O2, CO, H2S, FL-CAT)
Response Time:T50 = <15s, T90= <30s (FL CAT and IR sensors)
IP Rating:IP66 in accordance with EN60529:1992
Operating:Temperature -40ºC to +65ºC/ -40ºF to +149ºF.
Operating:Humidity Continuous 20-90%RH (non condensing), Intermittent 10-99%RH (non condensing)
Operating:Pressure 90-110kPa
Storage:Conditions -25°C to +65°C (-13°F to +149°F)
Features of Honeywell Sensepoint XCD Single -Gas Detector
1.Common transmitter platform
2.Clear and informative display
3.Multiple signal outputs
4.Surecell TM and ReflexTM
5.Infrared sensing technologythrhgrfhgrfh
6.Non-intrusive operation
7.Housing material options
8.Easy to install
Product Description of Honeywell Sensepoint XCD Single -Gas Detector
The Sensepoint XCD (Exceed) range of fixed gas detectors is used to monitor areas where flammable,oxygen deficiency and toxic gases may pose a hazard to working environments. Incorporating all the advantages of leading edge, fixed industrial gas detection technology, XCD offers high performance and reliability synonymous with the Honeywell brand.XCD is designed for a broad spectrum of industrial applications with a comprehensive choice of features and benefits in a truly cost effective package.
Company Advantage
1.5% lower prices than other competitors
2.Fast delivery
Parts of products are available in stock and can send within 3 working days
3.100% Inspection before Shipment
4.More than 10 years of export experience
5.Certificates UL Class,CSA, ATEX,IECEx, CE, CQST
6.After-sales Service
All the products have 1 year warranty, and It will be free from maintenance within warranty period, products over warranty period for paid services.