Honeywell Sensepoint XCD Gas Leak Detector Refrigerant Detector Technical Parameters
Use:3-wire, 4-20mA, gas detector transmitter for use with directly installed flammable and toxic gas sensors. For the protection of personnel and plant from flammable and toxic gas hazards.
Input Voltage Range: STD&RFD: 16 to 32Vdc (24Vdc nominal), RTD: 18 to 32Vdc (24Vdc nominal)
Power Consumption: ECC = 3.7W, IR = 3.7W, Cat = 4.9W
Current output:4-20mA (Source or Sink)
≥0.0<1.0 mA Fault
4.0 mA to 20.0 mA Normal gas measurement
2.0 mA or 4.0 mA (17.4 mA) Inhibit (during configuration/user settings)
22.0 mA Maximum over range
Terminals:15 (STD), 18(RTD&RFD) x screw terminals suitable for wire diameter 0.5mm 2(20AWG) to 2.5mm 2 (13AWG)
Relays:3 x 5A@250VAC. Selectable normally open or normally closed (Terminal) and
energized/de-energized (programmable)
Communication:RS485 Modbus RTU
Transmitter Material:Epoxy painted LM25 Aluminium. Stainless Steel 316
Sensor Material:Stainless Steel 316
Weight:LM25 Aluminium Alloy :2.4kg. Stainless Steel 316: 4.5 kg
Mounting:Pole or wall mounting
Entries:2 x M20 (or 2 x ¾”NPT) field cable entries, 1 x M25 sensor entry
Repeatability:+/- 1% of FSD
Linearity:+/- 1% of FSD
Accuracy:< +/- 5% of FSD (O2, CO, H2S, FL-CAT)
Response Time:T50 = <15s, T90= <30s (FL CAT and IR sensors)
IP Rating:IP66 in accordance with EN60529:1992
Operating:Temperature -40ºC to +65ºC/ -40ºF to +149ºF.
Operating:Humidity Continuous 20-90%RH (non condensing), Intermittent 10-99%RH (non condensing)
Operating:Pressure 90-110kPa
Storage:Conditions -25°C to +65°C (-13°F to +149°F)
Features of Honeywell Sensepoint XCD Gas Leak Detector Refrigerant Detector
1.Common transmitter platform
2.Clear and informative display
3.Multiple signal outputs
4.Surecell TM and ReflexTM
5.Infrared sensing technologythrhgrfhgrfh
6.Non-intrusive operation
7.Housing material options
8.Easy to install
Product Description of Honeywell Sensepoint XCD Gas Leak Detector Refrigerant Detector
Company Advantage
1.5% lower prices than other competitors
2.Fast delivery
Parts of products are available in stock and can send within 3 working days
3.100% Inspection before Shipment
4.More than 10 years of export experience
5.Certificates UL Class,CSA, ATEX,IECEx, CE, CQST
6.After-sales Service
All the products have 1 year warranty, and It will be free from maintenance within warranty period, products over warranty period for paid services.
Honeywell Sensepoint XCD Gas Leak Detector Refrigerant Detector Technical Parameters
Use:3-wire, 4-20mA, gas detector transmitter for use with directly installed flammable and toxic gas sensors. For the protection of personnel and plant from flammable and toxic gas hazards.
Input Voltage Range: STD&RFD: 16 to 32Vdc (24Vdc nominal), RTD: 18 to 32Vdc (24Vdc nominal)
Power Consumption: ECC = 3.7W, IR = 3.7W, Cat = 4.9W
Current output:4-20mA (Source or Sink)
≥0.0<1.0 mA Fault
4.0 mA to 20.0 mA Normal gas measurement
2.0 mA or 4.0 mA (17.4 mA) Inhibit (during configuration/user settings)
22.0 mA Maximum over range
Terminals:15 (STD), 18(RTD&RFD) x screw terminals suitable for wire diameter 0.5mm 2(20AWG) to 2.5mm 2 (13AWG)
Relays:3 x 5A@250VAC. Selectable normally open or normally closed (Terminal) and
energized/de-energized (programmable)
Communication:RS485 Modbus RTU
Transmitter Material:Epoxy painted LM25 Aluminium. Stainless Steel 316
Sensor Material:Stainless Steel 316
Weight:LM25 Aluminium Alloy :2.4kg. Stainless Steel 316: 4.5 kg
Mounting:Pole or wall mounting
Entries:2 x M20 (or 2 x ¾”NPT) field cable entries, 1 x M25 sensor entry
Repeatability:+/- 1% of FSD
Linearity:+/- 1% of FSD
Accuracy:< +/- 5% of FSD (O2, CO, H2S, FL-CAT)
Response Time:T50 = <15s, T90= <30s (FL CAT and IR sensors)
IP Rating:IP66 in accordance with EN60529:1992
Operating:Temperature -40ºC to +65ºC/ -40ºF to +149ºF.
Operating:Humidity Continuous 20-90%RH (non condensing), Intermittent 10-99%RH (non condensing)
Operating:Pressure 90-110kPa
Storage:Conditions -25°C to +65°C (-13°F to +149°F)
Features of Honeywell Sensepoint XCD Gas Leak Detector Refrigerant Detector
1.Common transmitter platform
2.Clear and informative display
3.Multiple signal outputs
4.Surecell TM and ReflexTM
5.Infrared sensing technologythrhgrfhgrfh
6.Non-intrusive operation
7.Housing material options
8.Easy to install
Product Description of Honeywell Sensepoint XCD Gas Leak Detector Refrigerant Detector
The Sensepoint XCD (Exceed) range of fixed gas detectors is used to monitor areas where flammable,oxygen deficiency and toxic gases may pose a hazard to working environments. Incorporating all the advantages of leading edge, fixed industrial gas detection technology, XCD offers high performance and reliability synonymous with the Honeywell brand.XCD is designed for a broad spectrum of industrial applications with a comprehensive choice of features and benefits in a truly cost effective package.
Company Advantage
1.5% lower prices than other competitors
2.Fast delivery
Parts of products are available in stock and can send within 3 working days
3.100% Inspection before Shipment
4.More than 10 years of export experience
5.Certificates UL Class,CSA, ATEX,IECEx, CE, CQST
6.After-sales Service