Fixed Gas Detector

Fixed Gas Detector

TC100N Fixed Point Gas Leak Detector To Detect Hydrogen Gas

TC100N Fixed Point Gas Leak Detector To Detect Hydrogen Gas

TC100N is a fixed point gas leak detector, generally used in industrial environments. It can detect the concentration of hydrogen sulfide gas to ensure the safety of workers.

Email: info@hn-guangqun.com
Phone: +86-13838155309

Live Chat    Leave Message

Detailed Product Description

Fixed Gas Detector Description
TC100N is a fixed point gas detector installed in a place where potential gas hazard exists to measure oxygen, toxic gas and combustible gas. With ATEX approval, it is suitable for explosive environment use. it communicates with the control panel through 4-20mA analog output or RS485 digital signal. 

The fixed gas detector is uesd forSteelworks, Petrochemical plants, Shipyards, Water treatment plants, Mines. Power plants, Food industry etc.

Fixed Gas Detector Key Features

  • ATEX approved
  • 4-20mA analog or RS485 digital output
  • 2 relay output for 4-20mA type
  • Sensor module design, easy for replacement

Fixed Gas Detector Detection Method

Natural diffusion is to use natural air flow to slowly flow the gas into the instrument for detection as the air flows freely, so as to obtain the results. Natural diffusion can accurately check whether the air contains toxic and harmful substances in real time. It is generally used in open places, such as open workshops. This method is affected by the detection environment, such as ambient temperature, wind speed, etc.

Fixed Gas Detector Specifications

Measuring gas
O2
CO
H2S
Combustible
Measuring range
0-25%vol
0-500ppm
0-100ppm
0-100%LEL
Resolution0.1%vol1ppm1ppm1%LEL
Sensor type
Electrochemical
Electrochemical
Electrochemical
Catalytic
Sensor life1 year2 years2 years
2 years
Sampling method
Natural diffusion
Response time

Toxic gas and O2: T90≤60s;

Combustible: T90≤30s

Working temperature
-20℃~50℃ for toxic gas
-40℃~70℃ for combustible gas
Signal output
4-20mA/RS485
Alarm output signal
2 programmable relays for 4~20mA type
Conduit connection
G1/2
Cable required
≥1.5mm2×3 core cable(4-20mA type)
≥1.5mm2×4 core cable(RS 485 type)
Transmission distance
≤1000m
Mounting type
Wall mounted
Working temperature
Toxic gas: -20℃~ 50℃
Combustible gas: -40℃~ 70℃
Working humidity
≤95%RH (no condensation)
Operation voltage
DC24V±25%
Consumption
<2W
Ingress Protection
IP65
Housing material

Chamber: Aluminum alloy

Sensor cover: Stainless steel

Dimension and weight
196mm×186mm×68.5mm, about 1.2kg
Approval
Ex Ⅱ 2G  Ex db llC T6 Gb
Cable / distance

4-20mA type: 1.5 MM2, 3 wire, shielded,1000m (maximum) 

RS485 type: 1.5 MM2, 4 wire, shielded, 1000m (maximum)

Recent product

GTQ-BS03 Multi Gas Detector To Detect Natural Gas

GTQ-BS03 Multi Gas Detector To Detect Natural Gas

BS03 Multi Gas Detector For Industrial Comprehensive safety

BS03 Multi Gas Detector For Industrial Comprehensive safety

TC100N Fixed Gas detector To Detect Multi Gas

TC100N Fixed Gas detector To Detect Multi Gas

GTQ-WD6200 Fixed Gas Detector For Industrial Gas Safety

GTQ-WD6200 Fixed Gas Detector For Industrial Gas Safety

GTQ-WD2200 Fixed Gas Leak Detector With Gas Alarm

GTQ-WD2200 Fixed Gas Leak Detector With Gas Alarm

GTQ-BS03 Fixed Gas Detector To Ensure Gas Safety

GTQ-BS03 Fixed Gas Detector To Ensure Gas Safety

BS03 Multi Gas Detector To Detect Natural Gas

BS03 Multi Gas Detector To Detect Natural Gas

TC100N Multi Gas Leak Detector For Industrial Gas

TC100N Multi Gas Leak Detector For Industrial Gas