BS03 Multi Gas Leak Detector For Industrial Gas
BS03 Multi Gas Leak Detector is designed to accurately detect gas concentrations. Ensure safety with precise monitoring in various environments.
Email:
info@hn-guangqun.com
Phone:
+86-13838155309
Detailed Product Description
BS03 is a fixed gas detector installed in a place where potential gas hazard exists to measure oxygen, toxic gas and combustible gas. It shows not only the concentration of gas but also diagnostic result of the unit itself through the LED screen and LED lights and can be connected to the control panel with a standard 4-20mA analog output.
Fixed Gas Detector Application
It is applicable to explosion-proof places: Steelworks, Petrochemical plants, Shipyards, Watertreatment plants, Mines, Power plants, Food industry etc.
Different sampling methods
Natural diffusion is that the gas in the detected area flows slowly into the instrument for detection with the free flow of air, and needs to be placed on site. This method is affected by the detection environment, such as ambient temperature, wind speed, etc., and is not suitable for gas sources with low pressure. The advantage is low cost.
The pump suction type is that the instrument is equipped with a gas sampling pump. Its working method is that the power supply drives the gas sampling pump to extract and sample the gas in the test area, and then the sample gas is sent to the instrument for detection.The characteristics are fast detection speed, long-distance measurement of dangerous areas, and safety of maintenance personnel. It is suitable for occasions where the gas detector cannot be placed on site and has special requirements for reaction speed, pressure difference, etc.
Fixed Gas Detector Specification
Measuring gas | Combustible | Catalytic sensor/ NDlR sensor |
Toxic gas & O2 | Electrochemical sensor | |
CO2 gas | NDlR sensor | |
VOCs | PID sensor | |
Measuring range | Refer to our gas list | |
Measuring accuracy | +5%F.S. | |
Sensor life | Catalytic sensor: 3 years Electrochemical: 2 years (1 year for O2 sensor) NDlR sensor: 5 years PiD sensor: 0.6 to 1 year | |
Measuring type | Diffuse naturally | |
Signal output | 4-20mA | |
Alarm output signal | 2 programmable relays | |
Cable / distance | 1.5 MM2 , 3wire, shielded, 1000m (maximum) | |
Conduit connection | G3/4 | |
Response time | Catalytic sensor: T90≤30s Electrochemical: T90≤60s NDlR sensor: T90≤10s PlD sensor: T90≤10s | |
Mounting type | Wall mounted | |
Working temperature | Toxic gas: -20°C~+50°C Combustible: -40°C~+70°C | |
Working humidity | ≤95%RH(no condensation) | |
Operation voltage | DC24V+25% | |
Consumption | <2W | |
Ingress Protection | IP65 | |
Housing material | Chamber: Aluminum alloy Sensor cover: Stainless steel | |
Dimension and weight | 162mm×208mm×103.5mm, about 2.1kg | |
Approval | Ex II 2G Ex db IIC T6 Gb |