AT8100 advanced fuel cell breathalyzer
AT8100 fuel cell breathalyzer has Keyboards operation panel, which is very easy and convenient to operate.
Email:
info@hn-guangqun.com
Phone:
+86-13838155309
Detailed Product Description
Alcohol Tester Description
Keyboards operation panel make AT8100 fuel cell breathalyzer has very easy and convenient operational function. Its core component adopts new Electrochemical Sensor which can measure accurately concentration of the breath alcohol, with strong anti-interface ability. It also has Bluetooth printing function, one-off anti-return mouthpiece ensures the health and safety of users.
Alcohol Tester Use suggestion
1. It is recommended to test 20 minutes after drinking. This is because it takes about 20 minutes for alcohol to be absorbed into the bloodstream through the digestive system, and about that long for the remaining alcohol in the mouth to dissipate.
2. Avoid alcohol tester in strong winds or closed rooms with dirty air.
3. Do not blow cigarette smoke into the instrument, which will damage the sensor. It is recommended that you wait one minute after smoking before testing.
4. Do not blow smoke into the air hole, do not enter the liquid in the air hole, do not block the air hole.
Alcohol Tester Information
- Passive and active test
- Adjustable alarming threshold
- Colorful LCD indication
- Portable thermal printer and data uploading
- Sensor type: Fuel cell
- Option: Bluetooth printer
- rechargable
Alcohol Tester Features
- Fuel cell sensor-accuracy and reliance
- Passive and active test
- Adjustable alarming threshold
- Anti-backflow mouthpiece for health and safety
- Colorful LCD indication
- Real temperature and time indication
- Switchable result units(mg/l, g/l, %BAC, ‰BAC)and temperature scale(℃, ℉)
- Testing records (maximum 2000) review
- Password management
- Portable thermal printer and data uploading
Alcohol Tester Application
Police station, traffic management, factory, workshop, office, car, hotel, mine, etc.Alcohol Tester Specification
Sensor type | Fuel cell |
Detection range | 0.00 - 0.40%BAC, 0.00-4.00‰BAC |
Accuracy | ± 0.005 at 0.05%BAC |
Pre-set level | 0.05%BAC; 0.50‰BAC; 0.25mg/L; 0.50g/L |
Warm-up time | <10 seconds |
Testing time | < 5 Sec |
Display | 1.44-inch LCD |
Power | 2×AA batteries |
Working environment | 0℃ - 50℃, ≤95% RH, No dews |
Working time | >2000 blowing times (full charge) |
Dimensions | 122mm X 67mm X 31mm @120g |
Testing records | 2,000 |
Option | Bluetooth printer |