E1000 Portable Single Gas To Detect Combustible Gas
E1000 is a portable single gas detector for individual use that can detect the surrounding combustible gases, such as methane gas. It can effectively ensure the gas safety in the industrial working environment.
Email:
info@hn-guangqun.com
Phone:
+86-13838155309
Detailed Product Description
Portable Gas Detector Description
E1000 is a portable rechargeable single gas detector. It can detect the concentration of combustible gases, oxygen and toxic gases in the surrounding environment, and send out information when an abnormality occurs. It’s easy for replacement and maintenance by the user himself with adopting smart sensor module.
It is applicable to explosion-proof places: teelworks, petrochemical plant, oil industry, shipbuilding yard, sewage treatment plant, mine, power supply works etc.
Portable Gas Detector Key Features
- Real-time clock
- Smart interchangeable sensor module
- Calibration point adjustable
- Two alarm level
- STEL alarm and TWA alarm for toxic gases
- Visual, audible, vibrating alarm
- Self protection against high concentration combustible gas
- Low battery alert
- Data uploading
- Password management
- Self-test when power on
- Self-diagnostic and self-correction function
- GPS, GPRS and Man-down function optional
Different sampling methods
Natural diffusion is that the gas in the detected area flows slowly into the instrument for detection with the free flow of air, and needs to be placed on site. This method is affected by the detection environment, such as ambient temperature, wind speed, etc., and is not suitable for gas sources with low pressure. The advantage is low cost.
The pump suction type is that the instrument is equipped with a gas sampling pump. Its working method is that the power supply drives the gas sampling pump to extract and sample the gas in the test area, and then the sample gas is sent to the instrument for detection.The characteristics are fast detection speed, long-distance measurement of dangerous areas, and safety of maintenance personnel. It is suitable for occasions where the gas detector cannot be placed on site and has special requirements for reaction speed, pressure difference, etc.
Portable Gas Detector Specifications
Measuring gas | O2 | CO | H2S | Combustible |
Measuring range | 0-25%vol | 0-500ppm | 0-100ppm | 0-100%LEL |
Sensor type | Electrochemical | Catalytic | ||
Sampling method | Natural diffusion | |||
Working temperature | -20℃~50℃ for toxic gas -40℃~70℃ for combustible gas | |||
Working humidity | <95%RH (no dews) | |||
Accuracy | ±5% FS | |||
Response time | T90<30s | |||
Alarm sound | ≥80dB @ 1m | |||
Power source | DC3.7V 1800mAh Lithium battery | |||
Charging time | 4h~6h | |||
Working time | Combustible gas: ≥8h Toxic gas: ≥300h(20℃) | |||
Ingress protection | IP66 | |||
Explosion-proof grade | Exib Ⅱ CT4 | |||
Event log | 10,000 events | |||
Housing | Rubber enclosure | |||
Standard accessories | Operation manual, calibration cap, charge, screwdriver | |||
Optional function | Data upload through USB cable | |||
Dimension | 108.4mm×61mm×36mm | |||
Weight | About 191g |