BX616 Gas Flame Detection To Detect Oxygen Gas
BX616 is a gas flame detection, which could detect flammable gas in the industrial environment.It can detect the oxygen gas concentration, so it is an oxygen gas detector.
Email:
info@hn-guangqun.com
Phone:
+86-13838155309
Detailed Product Description
Portable Gas Detector Description
BX616 portable four-gas detector can make continuous detection to combustilbe and toxic gasesto protect the disasters caused by the O2 deficiency, toxic gas poisoning and combustible gas. Once the gas concentration is abnormal, it sends out an alarm.It is suitable for steel plant, petrochemical plant, petroleum industry, shipbuilding yard, sewage treatment plant, mine, power supply engineering, confined space, etc.
Portable Gas Detector Specifications
Measuring gas | O2 | CO | H2S | H2/Combustible |
Measuring range | 0-25%VOL | 0-500ppm | 0-100ppm | 0-100%LEL |
Sensor type | Electrochemical | Electrochemical | Electrochemical | Catalytic |
Measuring type | Diffuse naturally | |||
Response time | T90<30s | |||
Display | LCD screen | |||
Audible | ≥85dB at 1m | |||
Alarm method | Visual, audible and vibrative signals | |||
Battery | DC3.7V 1800mAh Lithium battery | |||
Operating life | ≥8h per charge (Charging time: 4-6h) | |||
Event log | 2000 events | |||
Working temperature | Toxic gases: -20℃~50℃ Combustible: -40℃~70℃ | |||
Working humidity | <95%RH (no condensation) | |||
Housing | Rubber enclosure | |||
Standard accessories | Operation manual, calibration cap, charger, screwdriver | |||
Ex grade | II 2G Ex ia IIC T4 Ga II 2G Ex db ia IIC T4 Gb | |||
Ingress protection | IP66 | |||
Dimension | 120mm×68mm×30mm | |||
Weight | About 220g |
- 100, 000 detected records including peak value
- Calibration point adjustable
- Two alarm level for each sensor channel
- STEL& TWA alarm for toxic gases
- Visual/audible/vibrating alarm
- Self protection against high concentration combustible gas
- Low battery alert
- Confidence beep
- Data uploading
- Password management
- Self-test when power on
- Self-diagnostic and self correction function