BZ100 Standlone Portable Gas Detector To Gas Safety
BZ100 is a standalone gas detector, which could detect toxic and combustible gas in industrial enironment to ensure the gas safety.
Email:
info@hn-guangqun.com
Phone:
+86-13838155309
Detailed Product Description
Portable Gas Detector Description
BZ100N single gas detector that can detect the concentration of CO, H2S and O2 in the ambient air. With ultra-low-consumption and lightweight design, it is the smallest detector from China, only the size of a palm.
Portable Gas Detector Key Features
- The smallest detector from China (palm size)
- 2-year disposable gas detector
- Low-consumption 16-bit MCU to ensure long battery life
- Wide viewing-angle graphic LCD display
- Configurable high and low alarm points, two levels of alarm
- Battery low voltage alert
- Automatic calibration to reduce detection error
- Data upload function (Bluetooth)
- STEL and TWA alarms for toxic gases
- Automatic self-test function after power-on
- ATEX and IECEx approved
Portable Gas Detector Application
It is suitable for petroleum, chemical, metallurgy, mining, underground pipeline, tunnel and other industries.
Portable Gas
Detector Sensor Construction
Electrochemical sensor has two or three electrodes in contact with the electrolyte, and occasionally four electrodes. The typical electrodes are composed of a large surface area noble metal and a porous hydrophobic membrane. The electrodes and electrolyte are in contact with the surrounding air and are monitored by the porous membrane. Mineral acids are generally used as electrolytes. However, some sensors also use organic electrolytes. The electrodes are generally placed in a plastic box with gas inlet holes and electrical contacts.
Portable Gas Detector Specifications
Sampling method | Natural diffusion | ||
Sensor type | Electrochemical sensor | ||
Display deviation | O2 | CO | H2S |
±2%F.S. | Absolute:±5ppm Relative:±10% | Absolute:±2ppm Relative:±10% | |
Alarm signal | Audible, visual, and vibrative | ||
Alarm sound | ≥80dB @ 1m | ||
Communication method | Wireless(infrared commuication with host computer) | ||
Parameter setting, log storage and export functions | Parameter setting, log storage and export functions | ||
Indication method | LCD screen: show real-time data and system status. Backlight: illuminates on command or alarm status in low light. | ||
Ambient condition | Temperature: -20℃~50℃ Humidity: <95%RH (no condensation) Pressure: 90-110Kpa | ||
Power source | Lithium battery DC3.6V, 1200mAh | ||
Sensor lifespan | 2 years (2 minutes of alarm per day) | ||
Ingress protection | ≥IP66 | ||
Approval | ATEX II 1G Ex iaⅡC T4 Ga IECEx Ex ia IIC T4 Ga | ||
Explosion-proof type | Intrinsically safe | ||
Dimension | 61.5mm×52.8mm×27mm | ||
Weight | About 85g |