Gas Detector

Portable Gas Detector

E6000 Gas Leak Detector With Gas Detector Alarm

E6000 Gas Leak Detector With Gas Detector Alarm

E6000 is a gas leak detector that can measure up to multi gases in the surrounding environment with gas alarm when the gas concentration is abnormal.

Email: info@hn-guangqun.com
Phone: +86-13838155309

Live Chat    Leave Message

Detailed Product Description

Portable Gas Detector Description
E6000 is a portable model with multiple gas detectors. It can continuously measure the concentrations of up to six combustible gases, oxygen, and toxic gases in the surrounding environment, and issue an alarm when the gas levels are abnormal.It adopts interchangeable smart sensor modules, easy to replace the sensors and maintenance.It is applicable to explosion-proof places: teelworks, petrochemical plant, oil industry, shipbuilding yard, sewage treatment plant, mine, power supply works etc.

Portable Gas Detector Key Features

  • Interchangeable smart sensor module
  • Intrinsically safe
  • Built-in sampling pump (optional)
  • Visual, audible and vibration alarm
  • Adjustable alarm levels and span calibration values
  • Password management
  • Self-test after power on
  • Self-diagnostic and self-correction function
  • Real-time clock

Different sampling methods
1. Natural diffusion is that the gas in the detected area flows slowly into the instrument for detection with the free flow of air, and needs to be placed on site. This method is affected by the detection environment, such as ambient temperature, wind speed, etc., and is not suitable for gas sources with low pressure. The advantage is low cost.
2. The pump suction type is that the instrument is equipped with a gas sampling pump. Its working method is that the power supply drives the gas sampling pump to extract and sample the gas in the test area, and then the sample gas is sent to the instrument for detection.
The characteristics are fast detection speed, long-distance measurement of dangerous areas, and safety of maintenance personnel. It is suitable for occasions where the gas detector cannot be placed on site and has special requirements for reaction speed, pressure difference, etc.

Portable Gas Detector Specifications

Measuring gas
combustible gas, toxic gas
Measuring range
Please refer to our gas list
Sensor type
Catalytic sensor, electrochemical sensor, NDIR sensor, PID
sensor
Sensor life
Catalytic sensor: 3 years
Electrochemical: 2 years (1 year for O2 sensor)
NDIR sensor: 5 years
PID sensor: 0.6 to 1 year
Measuring type
Diffusion naturally or pump sampling
Response type
Catalytic sensor: T90≤30s
Electrochemical: T90≤60s
NDIR sensor: T90≤10s
PID sensor: T90≤10s
Alarm method
<95%RH (no condensation)
Ingress protection
IP67
Audible±5% FS
Battery
DC3.6V 6600mAh Lithium-ion battery
Ex grade
Ex d ib IIC T4 Gb / Ex ib D21 T4
Event log
≥80dB @ 1m
Working
temperature
Toxic gases,O2:-20~50℃
Combustible gases:-40~70℃
Humidity
<95%R.H.(no dews)
Standard
accessories
Operation manual, calibration cap, charger, USB cable.
software, suitcase
Housing
Rubber enclosure
Dimension
168mm*91mm*45mm
Weight
About 500g

Recent product

BX616 Standalone Gas Detector For Gas Leak

BX616 Standalone Gas Detector For Gas Leak

E6000 Industrial Gas Detector To Detect Flammable Gas

E6000 Industrial Gas Detector To Detect Flammable Gas

E4000 Leak Detectors To Detect Flammable Gas

E4000 Leak Detectors To Detect Flammable Gas

E1000 Portable Single Gas To Detect Combustible Gas

E1000 Portable Single Gas To Detect Combustible Gas

BZ100 Industrial Gas Leak Detector To Detect Flammable and Natural Gas

BZ100 Industrial Gas Leak Detector To Detect Flammable and Natural Gas

BX176 Portable Single Gas Detector To Detect Oxygen Gas

BX176 Portable Single Gas Detector To Detect Oxygen Gas

BX171 Gas Flame Detection To Detect Toxic Gas

BX171 Gas Flame Detection To Detect Toxic Gas

BX616 Gas Flame Detection To Detect Oxygen Gas

BX616 Gas Flame Detection To Detect Oxygen Gas