BX616 Industrial Gas Leak Detector
BX616 is a portable multi gas detector for continuous detecting of CH₄, CO, O₂ and H₂S, it is applicable to gas leakage in many explsion-proof places.
Email:
info@hn-guangqun.com
Phone:
+86-13838155309
Detailed Product Description
Portable Gas Detector Description
BX616 portable four-gas detector can make continuous detection to combustilbe and toxic gasesto protect the disasters caused by the O2 deficiency, toxic gas poisoning and combustible gas(CH4).Once the gas concentration is abnormal, it sends out an alarm.
Portable Gas Detector Application
It is suitable for steel plant, petrochemical plant, petroleum industry, shipbuilding yard, sewage treatment plant, mine, power supply engineering, confined space, etc.
Portable Gas Detector Working Principle
Gas detectors can be divided into electrochemical gas detectors, infrared gas detectors, thermal magnetic gas detectors, semiconductor gas detectors, ultraviolet gas detectors, etc. according to the principle of gas sensors.
The model of this product is E6000, and the gas sensor type is an electrochemical sensor. Its working principle is that the gas diffuses into the sensor, reaches the working electrode through the back of the porous membrane, and is oxidized or reduced on the working electrode. The electrochemical reaction generates a current, which passes through the external circuit. In addition to measuring, amplifying, and performing other signal processing functions, the external circuit also maintains the voltage across the sensor (for a two-electrode sensor, the voltage is between the working electrode and the counter electrode; for a three-electrode cell, the voltage is between the working electrode and the reference electrode). At the counter electrode, a reaction of equal magnitude and opposite direction occurs, that is, if the working electrode is an oxidation reaction, the counter electrode is a reduction reaction.
Portable Gas Detector Specifications
Measuring gas | O2 | CO | H2S | Combustible |
Measuring range | 0-25%VOL | 0-500ppm | 0-100ppm | 0-100%LEL |
Sensor type | Electrochemical | Catalytic | ||
Measuring type | Diffuse naturally | |||
Response time | T90<30s | |||
Display | LCD screen | |||
Audible | ≥85dB at 1m | |||
Alarm method | Visual, audible and vibrative signals | |||
Battery | DC3.7V 1800mAh Lithium battery | |||
Operating life | ≥8h per charge (Charging time: 4-6h) | |||
Event log | 2000 events | |||
Working temperature | Toxic gases: -20℃~50℃ Combustible: -40℃~70℃ | |||
Working humidity | <95%RH (no condensation) | |||
Housing | Rubber enclosure | |||
Standard accessories | Operation manual, calibration cap, charger, screwdriver | |||
Ex grade | II 2G Ex ia IIC T4 Ga II 2G Ex db ia IIC T4 Gb | |||
Ingress protection | IP66 | |||
Dimension | 120mm×68mm×30mm | |||
Weight | About 220g |